English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 80990/80990 (100%)
造訪人次 : 41986842      線上人數 : 1402
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋


    請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/94862


    題名: 光體積變化描記圖和踝肱指數聯合診斷週邊動脈疾病的潛力;The Diagnostic Potential of Combined Photoplethysmography and Ankle-Brachial Index in Peripheral Arterial Disease
    作者: 黃漢倫;Huang, Han-luen
    貢獻者: 生醫科學與工程學系
    關鍵詞: 周邊動脈疾病;踝肱指數;光體積變化描記圖;趾臂指數;都卜勒超音波;peripheral arterial disease;ankle-brachial index;photoplethysmography;toe-brachial index;duplex ultrasonography
    日期: 2024-08-20
    上傳時間: 2024-10-09 15:34:35 (UTC+8)
    出版者: 國立中央大學
    摘要: 周邊動脈疾病(peripheral arterial disease, PAD)與動脈粥狀硬化密切相關。在過去的幾十年中,全世界都推薦使用踝肱血壓指數(ankle-brachial pressure index)或稱踝肱指數(Ankle-brachial Index,ABI)來篩檢動脈粥狀硬化高危患者是否存在PAD的可能性。被確定患有PAD的患者可能受益於早期治療和嚴格的風險因子調整。ABI在診斷動脈明顯狹窄患者方面具有非常高的特異性。然而,ABI在動脈狹窄程度較低或有動脈鈣化的患者方面診斷的敏感度還不夠。治療準則建議進一步測量趾臂指數(toe-brachial index, TBI)或將運動心電圖(treadmill exercise test)與ABI相結合,以提高敏感度。光體積變化描記圖(photoplethysmography, PPG)是一種便攜式光學設備,也曾經用於檢測PAD,並被證實有足夠的靈敏度。ABI和PPG以不同的機轉檢測PAD。除了TBI和運動心電圖外,我們的研究主旨想確定ABI與PPG的結合在檢測PAD的診斷價值。
    我們利用兩年的時間招募了來自門診部或病房的130名患者。他們分別接受了ABI、PPG 和都卜勒超音波(duplex ultrasonography)檢查暨2年的預後追蹤。我們採用都卜勒超音波檢查來確立PAD的最終診斷,並藉此評估ABI、PPG 和這兩種組合的靈敏度、特異性和準確性。本研究中PPG檢查有2種方法,包括PPGratio和PPGamp。ABI的總體敏感性、特異性和準確性分別為55.9%、98.6%和80.3%;PPGratio為78.4%、87.2%和83.4%;PPGamp為75.7%、92.6%和85.3%;ABI加PPGratio組合為84.8%、86.4%和85.7%;ABI加PPGamp組合分別為81.1%、91.2%和86.9%。與單獨使用ABI或PPG相比,ABI和PPG的組合可以顯著提高診斷PAD的靈敏度及準確性。此外尤其是高風險患者,它還為主要心血管不良事件(MACE)和全因死亡率(all-cause mortality)提供了有價值的診斷見解。
    ;Peripheral arterial disease (PAD) is highly associated with atherosclerosis. It has been recommended worldwide to use the ankle-brachial pressure index, also called ankle-brachial index (ABI) to screen for the possibility of PAD in patients with a high risk of atherosclerosis in the past decades. Patients identified to have PAD may benefit from early treatment and strict risk factors modification. ABI has very high specificity in the diagnosis of PAD in patients with significant arterial stenosis. However, the sensitivity in patients with less severe stenosis or calcified arteries has been insufficient. Further measurement of the toe-brachial index (TBI) or the combination of the treadmill exercise test with ABI has been recommended to improve the sensitivity. Photoplethysmography (PPG), a portable optical device, was also used to detect PAD with adequate sensitivity. ABI and PPG detect PAD in different mechanisms. In addition to TBI and treadmill exercise test, our study was to determine the diagnostic value of ABI combined with photoplethysmography (PPG) in detecting PAD. Within 2 years, we included 130 patients from the outpatient department or ward. They all received ABI, PPG, duplex ultrasonography, and 2-year follow up respectively. Sensitivity, specificity, and accuracy were evaluated in ABI, PPG, and both combinations. The final diagnosis of PAD was confirmed by duplex ultrasonography. There were 2 methods for PPG examination in this study, including PPGratio and PPGamp. The overall sensitivity, specificity, and accuracy were 55.9%, 98.6%, and 80.3% in ABI; 78.4%, 87.2%, and 83.4% in PPGratio; 75.7%, 92.6%, and 85.3% in PPGamp; 84.8%, 86.4%, and 85.7% in ABI plus PPGratio combination; 81.1%, 91.2%, and 86.9% in ABI plus PPGamp combination, respectively. Integrating ABI and PPG significantly enhances sensitivity and accuracy in diagnosing PAD compared to using ABI or PPG individually. This combined approach improves diagnostic precision and provides crucial insights into predicting major adverse cardiovascular events (MACE) and all-cause mortality, particularly beneficial for high-risk patients.
    顯示於類別:[生物醫學工程研究所 ] 博碩士論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    index.html0KbHTML34檢視/開啟


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明